TERA Sensor Knowledge Center
Esc

Tapez pour chercher dans la documentation NextPM.

↑ ↓ naviguer↵ ouvriresc fermer

Firmware history

NB: user guide and Datasheet will always be updated accordingly to the latest active firmware version

May 2025 : 1047 Firmware update#

  • Modbus configuration of parity available
  • Unique internal serial number for identification of each NextPM with a command

Simplified protocol optimization:#

  • Possibility to activate or deactivate the heating system with simplified protocol
  • Total Suspended Particles (TSP) available
  • 5 channels available
  • Improved temperature and relative humidity measurement

Modbus optimization:#

  • Sleep mode
  • Calibration parameters implemented internally as y=ax+b function to give users the possibility to adjust PM concentration (only available for PM₁, PM₂.₅ and PM₁₀ in µg/m³)

Sept 2024: 1046 Firmware update#

  • Improvement of the temperature and relative humidity measures with and without heating system
  • Modification of the behaviour of the heating system, with automatic regulation shifting from 0% up to 100% if relative humidity exceeds 65%
  • New modbus registers added to get the particle size distribution on the whole range of measurement of the NextPM ,from 0.3-10µm in number of particle per liter
    • 0.3 - 0.5 µm
    • 0.5 - 1 µm
    • 1 - 2.5 µm
    • 2.5 - 5 µm
    • 5 - 10 µm
  • Total Suspended Particles (TSP) added to modbus register